ProLog-V8 Features Overview
PLUS all of the convenient operational features you have come to expect with Prolog:
Full featured logging form with all contact information and award status available at a glance. Field-to-field sequencing is fully customizable permitting you to order and utilize only the information fields you desire.
Sort your logbook by Date/Time, Callsign, DXCC, QTH, State, County, Province, CQZ, ITUZ, Continent, Grid Square, IOTA, Name, Note, Power, Contact Category, Prefix, QSL Manager, 1010 Number, VP Number or QSL Status.
Support for up to thirty-six logbooks each with its own award tracking.
Cross-merge data from one logbook to another; either in total, or using selective filtering.
Interactive PacketCluster to monitor DX Spots and WWV reports. Built-in support for standard TNC or Internet monitoring via DX-Summit or VE7CC. ProLog's Origination and Band Plan Filters coupled with our exclusive Callsign Alert Queue provide a powerful selective monitoring and alerting interface.
ProLog's DX Spot Window is color coded to let you quickly spot the "New Ones". To make it even easier, you can sort or prioritize the Spot List by Callsign, Date/Time, Band, Prefix, Continent, CQZ and ITUZ.
Supports all major callbook databases: our own CallMaster, Buckmaster, QRZ and SAM.
Integrate the contents of an external callbook database and the Prefix Database into each contact that comprises a logbook. This is a great feature for updating contest logs with complete information.
Bi-directional rig control for most of the popular models of transceivers from Kenwood, Yaesu (9000 Included), ICOM (7800 Included), TenTec, JST and others. You can also "Hot Switch" rigs directly from the ProLog Logging Form.
30 Built-in Memory Channels for quick QSY to your favorite frequencies and modes.
Compress and Backup your logbook to floppy, CDRW or ZIP disk with a single click.
Award tracking of DXCC, WAS, WAC, WAZ, WAITU, WPX, VUCC, IOTA, US Counties and 1010 for all Amateur bands and modes including the new PSK31 and MFSK modes complete with reports suitable for submission.
ProLog's exclusive "Traffic Signaling" award status panel visually alerts you to those contacts that will enhance your award Prefix, Band and Mode standings for all of the supported awards.
Automatic computation and display of Grid Square information.
Batch processing of QSL and address labels for trouble-free QSL'ing.
Special label format for responding to SWL reports.
Print multiple contacts on a single QSL label; great when you work that rare one on multiple bands and modes. Separate Font sizing for QSL and Address/Return Address Labels.
Generate your own return address labels with or without your callsign.
ProLog's
comprehensive report generator lets you display and print detailed
log and award reports that are suitable for award submission.
Optional integrated QSL Route Database with over 100,000 QSL routes.
Importation and Exportation of ADIF (Amateur Data Interchange Format) files is fully supported by ProLog. You may also export your logbook files in ".CSV" format for use with Microsoft Excel.
ProLog supports all models of the Dymo Label/Writer; both standard and turbo.
ProLog supports Hygain DCU, Orion 2800 and EZ-Rotor Controllers for the Hygain and Yaesu rotors.
Log contacts in real time directly from MixW or Digipan to the ProLog database!!
Extensive support for LoTW including automatic updating of your logbook from the LoTW report file.
Monitor DX-Spots directly from DX-Summit. DX Spot origination is also supported.
Enter your favorite websites and call them directly from Prolog. ProLog comes with preset links for Propagation and Grey line. Simply add your favorites to the list!
The Callsign Information Form permits you to directly access the GoogleMap™ website to display a detailed map showing the exact location of the Licensee.
Adjust the List Window color schemes to your preference.
ProLog's LoTW Membership Database quickly displays whether a given callsign is a member of LoTW. The database is updated monthly and is available at no charge via our FTP Website.
The "VariList" feature permits the user to designate what data will appear in the List Windows.
Full support for the logging of all 25 Digital Modes defined in the ADIF 2.0 Specification.
Daylight Savings Time Ready. Switch between Old and New (2007) Timeframes with a single click.
ProLog is supplied on CDROM and will run under Windows
2000/NT/XP/Vista/Win-7/Win-8 and Win-10 (32-64 bit versions). The optional QSL Route
Database requires 15 MB of hard disk space and the optional CallMaster
database requires an additional 150 MB. A Logbook containing 5000
contacts and award files will occupy an additional 10 MB of hard disk
space. If you intend to run both rig control and rotor control you will
require two dedicated serial or USB ports. As most transceivers and
rotor controllers utilize a standard RS-232C interface, and given the
fact that most of today's modern computers utilize only USB ports, will
necessitate the use of a USB to Serial Converter.
Contact Information
Tech Support and FAX --
Postal Address -- 5560 Jackson Loop NE -- Rio Rancho, NM 87144
For Comments or Questions, Please Use Our Contact Form
ProLog |
Order Now |
What's New? | Products and Services |
Support and FAQ's |
Links
Product Reviews
|
User Feedback |
Downloads |
Contact Us |
Discussion
Forum